+44 (0)161 339 3049

Economiser

Customer required an economiser to fit into existing space. Thermtech designed it to slot perfectly onto existing connections, minimising production downtime.

Project Details
  • Design pressure: 24 Bar g.
  • Design Temp: 250̊ C
  • Volume: 150 L
  • Desing code: BS EN 1292 PESR CATIII, Mod G
  • Boiler efficiency Increase: 6.8%
  • Savings per Annum: £36,973

Project Gallery

More Case Studies